{"id":830,"date":"2025-07-23T01:57:38","date_gmt":"2025-07-23T01:57:38","guid":{"rendered":"https:\/\/www.bhenlab.com\/?post_type=product&#038;p=830"},"modified":"2025-07-23T05:31:26","modified_gmt":"2025-07-23T05:31:26","slug":"boh-01b-maintenance-electrician-technician-and-senior-technician-skills-training-and-assessment-device","status":"publish","type":"product","link":"https:\/\/www.bhenlab.com\/ko\/product\/boh-01b-maintenance-electrician-technician-and-senior-technician-skills-training-and-assessment-device\/","title":{"rendered":"BOH-01B Maintenance Electrician Technician and Senior Technician Skills Training and Assessment Device"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">I. Overview<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">The senior technician skills training and assessment equipment needs to be applicable to the electrical control circuits required by the textbooks\u00a0<em>Junior Maintenance Electrician<\/em>,\u00a0<em>Intermediate Maintenance Electrician<\/em>, and\u00a0<em>Senior Maintenance Electrician<\/em>. Through training with the PLC programmable controller, frequency converter, and corresponding training modules equipped with the device, learners can quickly master the practical application technologies and operational skills required by the courses. It is targeted, practical, scientific, and advanced, meeting the requirements of the assessment outline for intermediate and senior maintenance electricians. It is an ideal equipment for vocational skill appraisal departments, colleges and universities, and technical schools to assess the skills of intermediate and senior maintenance electricians.<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">II. Technical Parameters<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(1) Input voltage: Three-phase four-wire (or three-phase five-wire) ~380V\u00b110% 50Hz<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(2) Working environment: Temperature -10\u2103~+40\u2103; Relative humidity &lt;85% (at 25\u2103); Altitude &lt;4000m<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(3) Device capacity: &lt;1.5KVA<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(4) Weight: Not less than 100Kg. Load-bearing capacity: Not more than 3000N\/\u33a1.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(5) Overall dimensions: Not less than 1700\u00d7700\u00d71630mm\u00b3.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(6) Leakage protection action current: \u226430mA; Leakage protection action time: \u22640.1s.<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">III. Configuration and Functions<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(1) The main control panel of the DW02 power control box is of a double-layer iron structure with matte dense texture spray coating, and the panel is made of aluminum.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(2) Three-phase four-wire power input, after passing through a leakage protector and a main switch, controls the on\/off of the contactor through start\/stop buttons, and is equipped with an emergency stop control button.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(3) The control panel is equipped with a 450V pointer-type AC voltmeter, which can observe the three-phase grid voltage through a band switch.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(4) Timer and alarm recorder (service manager), which is usually used as a clock, with functions such as setting time, timing alarm, and power cutoff; it can also automatically record the total number of leakage alarms and power short circuits caused by wrong wiring or operations, providing a unified standard for assessing students&#8217; practical skills.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(5) AC circuit measuring meter: 8-digit LED display, which can simultaneously measure current I, voltage V, power KW, electric energy KWh, and working time T in the working circuit. Accuracy: Class 1.0.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(6) AC low-voltage power supply: Equipped with an autotransformer with primary side 220V, secondary side 26V and 6.3V AC voltage. 6.3V is used for the signal indicator power supply, and 26V is used for the AC power supply of the rectifier circuit in energy-consuming braking.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(7) 4 pieces of 5408 diodes, used for the rectifier circuit of energy-consuming braking.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(8) Three 75\u03a9\/75W resistors for motor step-down startup, and one 10\u03a9\/25W resistor for asynchronous motor energy-consuming braking.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(9) Siemens CPU1214C PLC host, integrated with digital I\/O (14 digital inputs \/ 10 digital outputs).<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(10) Frequency conversion device (Siemens V20-0.4KW), powered by AC 220V, with a frequency control range of 0.2~400Hz, built-in EMC filter, output power 0.37kW. It integrates an RS485 communication interface and works in PWM mode (with vector control, sensorless vector speed\/torque control) and other working modes; input and output points are all led to the module panel, and connected to the controlled object through plug-in wires; it adopts a modular design, facilitating expansion and combination; it can be used independently or in conjunction with PLC and electrical practical operation unit boards.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(11) Touch screen training component (physical object): 7-inch STN 256-color: Understand the functions and usage methods of industrial touch screens, master communication knowledge with PLC, and master the implementation methods of function keys such as reset, set, and toggle, graphic (curve) display, and dynamic screen tracking in the touch screen.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">(12) The training desk is of a double-layer iron structure with matte dense texture spray coating, and the desktop is a fireproof, waterproof, and wear-resistant high-density board. The structure is firm, and the appearance is beautiful and elegant. The desk is equipped with two drawers (with locks) on each side and a cabinet, which can respectively place hanging parts and training items.<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">IV. Overall Configuration Table 1 of Maintenance Electrician Technician and Senior Technician Skills Training and Assessment Device<\/h2>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>\uc77c\ub828 \ubc88\ud638<\/th>\n<th>\uc774\ub984<\/th>\n<th>\ub2e8\uc704<\/th>\n<th>\uc218\ub7c9<\/th>\n<th>\ube44\uace0<\/th>\n<th>\ube44\uace0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Maintenance electrician training and assessment bench<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Overall dimensions: 1700mm\u00d7700mm\u00d71650mm; Material: Steel-wood structure; Meets relevant national environmental protection requirements; Input voltage: AC 380V\u00b110% 50Hz three-phase five-wire; Capacity: &lt;1.5kVA; Experiment panel: Used for hanging training unit boards<\/td>\n<td>Overall dimensions: 1700mm\u00d7700mm\u00d71650mm; Material: Steel-wood structure; Meets relevant national environmental protection requirements; Input voltage: AC 380V\u00b110% 50Hz three-phase five-wire; Capacity: &lt;1.5kVA; Experiment panel: Used for hanging training unit boards<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Electrical control training unit hanging box and motor<\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>DW-05<\/td>\n<td>Electrical skills training component (V)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>DW-06<\/td>\n<td>Maintenance electrician training component (I)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>DW-07<\/td>\n<td>Maintenance electrician training component (II)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>DW-08<\/td>\n<td>Maintenance electrician training component (III)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>DW-09<\/td>\n<td>Maintenance electrician training component (IV)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>HLDJ-01<\/td>\n<td>Single-phase capacitor-start motor, AC 220V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>HLDJ02<\/td>\n<td>Three-phase squirrel-cage motor AC 220V (Y)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>HLDJ03<\/td>\n<td>Three-phase squirrel-cage motor AC 380V (Y\/\u25b3, with speed relay)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>HLDJ04<\/td>\n<td>Two-speed asynchronous motor AC 380V (\u25b3\/YY)<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Instrument and lighting training hanging box<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>See Table 3<\/td>\n<td>See Table 3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Frequency converter training hanging box<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>(Siemens) V20-0.4KW frequency converter, with communication interface and BOP operation panel.<\/td>\n<td>(Siemens) V20-0.4KW frequency converter, with communication interface and BOP operation panel.<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>PLC host hanging box<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Siemens CPU1214c PLC host, integrated with digital I\/O (14 digital inputs \/ 10 digital outputs)<\/td>\n<td>Siemens CPU1214c PLC host, integrated with digital I\/O (14 digital inputs \/ 10 digital outputs)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>PLC training hanging box<\/td>\n<td>\ube14\ub85d<\/td>\n<td>1<\/td>\n<td>Answer device \/ musical fountain \/ assembly line \/ traffic lights \/ automatic water supply \/ Tian Ta Zhi Guang (Light of Tianjin Tower)<\/td>\n<td>Answer device \/ musical fountain \/ assembly line \/ traffic lights \/ automatic water supply \/ Tian Ta Zhi Guang (Light of Tianjin Tower)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>Automatic feeding and loading \/ four-section conveyor belt \/ multi-liquid mixing device \/ automatic vending machine \/ automatic rolling mill \/ mail sorter<\/td>\n<td>Automatic feeding and loading \/ four-section conveyor belt \/ multi-liquid mixing device \/ automatic vending machine \/ automatic rolling mill \/ mail sorter<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>Manipulator control \/ automatic forming machine \/ machining center<\/td>\n<td>Manipulator control \/ automatic forming machine \/ machining center<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>Four-story elevator \/ basic experiment \/ intermediate relay<\/td>\n<td>Four-story elevator \/ basic experiment \/ intermediate relay<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Motor guide rail and optical code disc speed measurement system<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Including one set of optical code disc speed measurement system (equipped with imported photoelectric encoder), one stainless steel guide rail, with good flatness, no stress deformation, and good concentricity<\/td>\n<td>Including one set of optical code disc speed measurement system (equipped with imported photoelectric encoder), one stainless steel guide rail, with good flatness, no stress deformation, and good concentricity<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Touch screen training component (physical object)<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Kunlun Tongtai, 7-inch STN 256-color<\/td>\n<td>Kunlun Tongtai, 7-inch STN 256-color<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>PLC simulation training software<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>(1) Real-time display of PLC operation status through PLASH virtual environment (2) PLC programming training, PLC program writing and testing functions (3) Realization of PLC operation simulation and error program checking<\/td>\n<td>(1) Real-time display of PLC operation status through PLASH virtual environment (2) PLC programming training, PLC program writing and testing functions (3) Realization of PLC operation simulation and error program checking<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Maintenance electrician power drag simulation software<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>3D modeling is intuitive, which can meet the needs of students for multimedia teaching of electrical component structure, function, installation, wiring, circuit analysis, and virtual wiring training and knowledge assessment test functions for familiarizing with electrical control circuits.<\/td>\n<td>3D modeling is intuitive, which can meet the needs of students for multimedia teaching of electrical component structure, function, installation, wiring, circuit analysis, and virtual wiring training and knowledge assessment test functions for familiarizing with electrical control circuits.<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Electrical connecting wires<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>20 pieces: 1000mm long &#8211; 6 yellow, 6 green, 6 red, 2 black; 10 pieces: 600mm long &#8211; 2 yellow, 2 green, 2 red, 2 blue, 2 black.<\/td>\n<td>20 pieces: 1000mm long &#8211; 6 yellow, 6 green, 6 red, 2 black; 10 pieces: 600mm long &#8211; 2 yellow, 2 green, 2 red, 2 blue, 2 black.<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Common tools<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>1 flat-blade screwdriver; 1 cross screwdriver; 1 wire stripper; 1 pointer multimeter; 1 diagonal pliers.<\/td>\n<td>1 flat-blade screwdriver; 1 cross screwdriver; 1 wire stripper; 1 pointer multimeter; 1 diagonal pliers.<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>Experiment instruction manual<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Guide students&#8217; training<\/td>\n<td>Guide students&#8217; training<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">Table 2: Configuration Description Table of Electrical Control Training and Assessment Hanging Boxes for Maintenance Electrician Technician and Senior Technician Skills Training and Assessment Device<\/h2>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>\uc77c\ub828 \ubc88\ud638<\/th>\n<th>\uc774\ub984<\/th>\n<th>\ub2e8\uc704<\/th>\n<th>\uc218\ub7c9<\/th>\n<th>\ube44\uace0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>DW-05 Electrical skills training component<\/td>\n<td><\/td>\n<td><\/td>\n<td>Provides two groups of 90\u03a9\u00d72\/1.3A disk resistors; one group of 900\u03a9\u00d72\/0.41A disk resistors.<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>DW-06 Maintenance electrician training component (I)<\/td>\n<td>\uc124\uc815<\/td>\n<td>1<\/td>\n<td>Provides 2 capacitors, 1 AC solenoid valve, 1 AC contactor, 3 thermal relays<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>DW-07 Maintenance electrician training component (II)<\/td>\n<td>\uc870\uac01<\/td>\n<td>1<\/td>\n<td>Provides 1 air switch, 2 3P fuses, 3 AC contactors.<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>DW-08 Maintenance electrician training component (III)<\/td>\n<td>\uc870\uac01<\/td>\n<td>1<\/td>\n<td>Provides 2 power-on delay time relays, 1 power-off delay time relay, 4 travel switches, 6 buttons of various colors<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>DW-09 Maintenance electrician training component (IV)<\/td>\n<td><\/td>\n<td><\/td>\n<td>Provides 4 AC contactors<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">Table 3: Configuration Description Table of Instrument and Lighting Training Hanging Boxes for Maintenance Electrician Technician and Senior Technician Skills Training and Assessment Device<\/h2>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>\uc77c\ub828 \ubc88\ud638<\/th>\n<th>Hanging Box Number<\/th>\n<th>Training Module Name<\/th>\n<th>\uc218\ub7c9<\/th>\n<th>\ube44\uace0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>DW-10<\/td>\n<td>Instrument and lighting training and assessment component (I)<\/td>\n<td>1 piece<\/td>\n<td>Provides 1 two-pole leakage protector, 2 3P fuses, 1 knife switch, 1 single-phase watt-hour meter<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>DW-11<\/td>\n<td>Instrument and lighting training and assessment component (II)<\/td>\n<td>1 piece<\/td>\n<td>Provides 2 screw lamp holders, 3 switch boxes, 1 ballast, 1 starter, 1 fluorescent lamp, 2 toggle switches, 1 double switch<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>DW-12<\/td>\n<td>Instrument and lighting training and assessment component (III)<\/td>\n<td>1 piece<\/td>\n<td>Provides 3 AC ammeters, 3 current transformers<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>DW-13<\/td>\n<td>Instrument and lighting training and assessment component (IV)<\/td>\n<td>1 piece<\/td>\n<td>Provides 1 AC voltmeter, 1 voltage indicator switch<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>DW-14<\/td>\n<td>Instrument and lighting training and assessment component (V)<\/td>\n<td>1 piece<\/td>\n<td>Provides 1 three-phase three-wire active watt-hour meter<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>DW-15<\/td>\n<td>Instrument and lighting training and assessment component (VI)<\/td>\n<td>1 piece<\/td>\n<td>Provides 1 three-phase four-wire active watt-hour meter<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>DW-16<\/td>\n<td>Instrument and lighting training and assessment component (VII)<\/td>\n<td>1 piece<\/td>\n<td>Provides 1 three-phase four-wire reactive watt-hour meter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">V. Training Projects<\/h2>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Direct start control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Inching control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Self-locking control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Button interlock forward and reverse control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Contactor interlock forward and reverse control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Double interlock forward and reverse control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Automatic reciprocating control circuit of three-phase asynchronous motor workbench<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Sequential start and stop control circuit of two three-phase asynchronous motors<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Two-place control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Y-\u25b3 control by contactor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Y-\u25b3 control by time relay<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Single-direction start reverse connection braking control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Single-direction start energy-consuming braking control circuit of three-phase asynchronous motor with transformerless half-wave rectification<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Single-direction start energy-consuming braking control circuit of three-phase asynchronous motor with transformer full-wave rectification<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Forward and reverse start energy-consuming braking control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Capacitor start control circuit of single-phase squirrel-cage motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Manual speed change control circuit of two-speed AC asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Automatic speed change control circuit of two-speed AC asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Y-\u25b3 start control circuit with power-off delay DC energy-consuming braking<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Forward and reverse energy-consuming braking control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Forward and reverse start reverse connection braking control circuit of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Electrical control circuit of C620 lathe<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Electrical control of electric hoist<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Control circuit of Y3150 gear hobbing machine<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Basic instruction operation of programmable controller<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">LED digital display control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of Tian Ta Zhi Guang (Light of Tianjin Tower) control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of crossroads traffic lights<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of manipulator actions<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of four-section conveyor belt<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of assembly line control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of five-phase stepping motor control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of water tower water level control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of liquid mixing device control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of mail sorter control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of rolling mill control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of automatic forming machine control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of automatic feeding and loading control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of fully automatic washing machine control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Simulation of electroplating production line control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled forward and reverse control of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled Y-\u25b3 start control of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled step-down start control of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled energy-consuming braking control of three-phase asynchronous motor<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Parameter setting and operation of frequency converter functions<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Alarm and protection functions of frequency converter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Multi-speed selection variable frequency speed regulation<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">External terminal inching control<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Control of motor forward and reverse movement<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Control of motor running time operation<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Parameter setting of frequency converter for momentary power failure<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">External voltage variable frequency speed regulation<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">External current variable frequency speed regulation<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Open-loop speed regulation of three-phase asynchronous motor by frequency converter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled frequency converter speed regulation<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Basic instruction programming practice based on touch screen control mode<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled LED control based on touch screen control mode<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">PLC-controlled manipulator control based on touch screen control mode<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Communication control among PLC, touch screen, and frequency converter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">485 bus network communication technology based on MCGS<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Socket and one switch controlling one lamp (incandescent lamp, fluorescent lamp + two-pole leakage switch)<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Two double switches controlling one lamp (incandescent lamp, fluorescent lamp + two-pole leakage switch)<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Three switches controlling one lamp (incandescent lamp, fluorescent lamp + two-pole leakage switch)<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring of fluorescent lamp circuit<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring of sound-controlled switch controlling incandescent lamp circuit<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring of touch delay switch controlling incandescent lamp circuit<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring of human body induction switch controlling incandescent lamp circuit<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Direct wiring circuit of single-phase watt-hour meter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of single-phase watt-hour meter through current transformer<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of voltmeter and ammeter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Voltage measurement wiring of voltmeter with universal changeover switch for three-phase voltage<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Control circuit wiring of single current transformer for single-phase circuit<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Star connection circuit of three current transformers<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Delta connection circuit of three current transformers<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Measurement circuit of three-phase power factor meter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase three-wire active watt-hour meter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase three-wire active watt-hour meter through current transformer<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase four-wire active watt-hour meter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase four-wire reactive watt-hour meter through current transformer<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase four-wire reactive watt-hour meter<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wiring circuit of three-phase four-wire reactive watt-hour meter through current transformer<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Step-down start control circuit of motor with series autotransforme<\/div>\n<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p class=\"header-vfC6AV auto-hide-last-sibling-br\">BOH-01B Maintenance Electrician Technician and Senior Technician Skills Training and Assessment Device<\/p>","protected":false},"featured_media":831,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[194],"product_cat":[182],"product_tag":[239,238],"class_list":{"0":"post-830","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-bhenlab","7":"product_cat-electrician","8":"product_tag-electrical-engineering-teaching-equipment","9":"product_tag-electrical-maintenance-equipment","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/product\/830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/comments?post=830"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/media\/831"}],"wp:attachment":[{"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/media?parent=830"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/product_brand?post=830"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/product_cat?post=830"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bhenlab.com\/ko\/wp-json\/wp\/v2\/product_tag?post=830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}