{"id":966,"date":"2025-09-10T08:34:42","date_gmt":"2025-09-10T08:34:42","guid":{"rendered":"https:\/\/www.bhenlab.com\/?post_type=product&#038;p=966"},"modified":"2025-09-10T08:34:42","modified_gmt":"2025-09-10T08:34:42","slug":"mesh-type-maintenance-electrician-training-device-dual-group-type","status":"publish","type":"product","link":"https:\/\/www.bhenlab.com\/es\/product\/mesh-type-maintenance-electrician-training-device-dual-group-type\/","title":{"rendered":"Mesh-Type Maintenance Electrician Training Device (Dual-Group Type)"},"content":{"rendered":"<h2>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-969 aligncenter\" src=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-500x500.png\" alt=\"\" width=\"500\" height=\"500\" srcset=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-500x500.png 500w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-300x300.png 300w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-768x768.png 768w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-12x12.png 12w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-150x150.png 150w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-75x75.png 75w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762-480x480.png 480w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u6b63\u9762.png 800w\" sizes=\"auto, (max-width:767px) 480px, 500px\" \/><\/h2>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-967 aligncenter\" src=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-500x500.png\" alt=\"\" width=\"500\" height=\"500\" srcset=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-500x500.png 500w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-300x300.png 300w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-768x768.png 768w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-12x12.png 12w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-150x150.png 150w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-75x75.png 75w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621-480x480.png 480w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97621.png 800w\" sizes=\"auto, (max-width:767px) 480px, 500px\" \/><\/h2>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-968 aligncenter\" src=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-500x500.png\" alt=\"\" width=\"500\" height=\"500\" srcset=\"https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-500x500.png 500w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-300x300.png 300w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-768x768.png 768w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-12x12.png 12w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-150x150.png 150w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-75x75.png 75w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622-480x480.png 480w, https:\/\/www.bhenlab.com\/wp-content\/uploads\/2025\/09\/\u4fa7\u97622.png 800w\" sizes=\"auto, (max-width:767px) 480px, 500px\" \/><\/h2>\n<h2><strong><b>I. Technical Performance<\/b><\/strong><\/h2>\n<p>1.Input Power Supply: Three-phase four-wire system ~380V\u00b110% 50Hz<\/p>\n<p>2.Temperature: -5\u2103\uff5e+40\u2103, Relative Humidity: &lt;85% (at 25\u2103)<\/p>\n<p>3.Device Capacity: &lt;1.5KVA<\/p>\n<p>4.Overall Dimensions: 1600mm\u00d7700mm\u00d71690mm<\/p>\n<h2><strong><b>II. Configuration of Training Bench<\/b><\/strong><\/h2>\n<p>1.Public Part: Equipped with voltage-type leakage protection and current-type leakage protection. There is an indicator light for external power input, and an emergency stop button. Press the button to cut off the main power supply of the training bench in case of emergency.<\/p>\n<p>2.Each group is provided with two types of power supplies: line voltage of 380V or phase voltage of 220V, as well as a single-phase power socket and a line voltage input indicator meter.<\/p>\n<p>3.Each group is provided with low-voltage AC power supplies of 3V, 6V, 9V, 12V, 18V, 24V and 36V.<\/p>\n<p>4.Each group is provided with one constant current and regulated power supply, with a voltage range of 0-30V and a maximum current of 3A. It is equipped with a built-in relay for automatic gear shifting and a multi-turn potentiometer for continuous adjustment, and a digital meter to indicate current and voltage values.<\/p>\n<p>5.The training table adopts a double-layer iron structure with matte dense-texture spray coating. The tabletop is made of high-density board that is fire-resistant, waterproof and wear-resistant. It has a solid structure and an elegant appearance. There are drawers on the left and right sides of the table, and a component storage cabinet at the bottom.<\/p>\n<h2><strong><b>III. Reference Training Projects<\/b><\/strong><\/h2>\n<p>1.Electrical Wiring Process Training<\/p>\n<p>2.Training on Circuit for Controlling One Lamp with Two Switches<\/p>\n<p>3.Training on Incandescent Lamp Circuit Controlled by Sound-Activated Switch<\/p>\n<p>4.Training on Circuit for Controlling One Lamp from Two Locations<\/p>\n<p>5.Training on Circuit for Controlling One Lamp from Three Locations<\/p>\n<p>6.Training on Wiring of Fluorescent Lamp Circuit<\/p>\n<p>7.Direct Installation and Wiring of Single-Phase Watt-Hour Meter<\/p>\n<p>8.Installation and Wiring of Single-Phase Watt-Hour Meter via Current Transformer<\/p>\n<p>9.Installation Training of Indoor Lighting Circuit<\/p>\n<p>10.Installation Training of Distribution Board<\/p>\n<p>11.Measurement of AC Load Power<\/p>\n<p>12.Direct Start Control of Three-Phase Asynchronous Motor<\/p>\n<p>13.Contactor Inching Control Circuit of Three-Phase Asynchronous Motor<\/p>\n<p>14.Contactor Self-Locking Control Circuit of Three-Phase Asynchronous Motor<\/p>\n<p>15.Y\/\u25b3 Automatic Control Circuit of Three-Phase Asynchronous Motor<\/p>\n<p>16.Forward and Reverse Rotation Control Circuit of Three-Phase Asynchronous Motor with Forward-Reverse Switch<\/p>\n<p>17.Forward and Reverse Rotation Control Circuit of Three-Phase Asynchronous Motor with Contactor Interlock<\/p>\n<p>18.Forward and Reverse Rotation Control Circuit of Three-Phase Asynchronous Motor with Button Interlock<\/p>\n<p>19.Forward and Reverse Rotation Control Circuit of Three-Phase Asynchronous Motor with Double Interlock<\/p>\n<p>20.Multi-Location Control of Three-Phase Asynchronous Motor<\/p>\n<p>21.Automatic Reciprocating Control Circuit of Workbench<\/p>\n<p>22.Series Resistor Step-Down Start Control Circuit of Three-Phase Asynchronous Motor<\/p>\n<p>23.Dynamic Braking Control Circuit of Three-Phase Asynchronous Motor<\/p>\n<h2><strong><b>IV. List of Components Required for Reference Training Projects (List for Each Group)<\/b><\/strong><\/h2>\n<p>Note: Each device needs to be equipped with two sets of components, and users can also purchase them by themselves.<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"184\">Serial Number<\/td>\n<td width=\"184\">Name<\/td>\n<td width=\"184\">Model and Specification<\/td>\n<td width=\"184\">Quantity<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">1<\/td>\n<td width=\"184\">Single-Phase Watt-Hour Meter<\/td>\n<td width=\"184\">DD862-2<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">2<\/td>\n<td width=\"184\">Single-Phase Knife Switch<\/td>\n<td width=\"184\">HK8<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">3<\/td>\n<td width=\"184\">Pull Switch<\/td>\n<td width=\"184\">4A\/250V<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">4<\/td>\n<td width=\"184\">Flat Lamp Holder<\/td>\n<td width=\"184\">6A\/250V<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">5<\/td>\n<td width=\"184\">Circular Socket<\/td>\n<td width=\"184\">T3-10<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">6<\/td>\n<td width=\"184\">Current Transformer<\/td>\n<td width=\"184\">LQG-0.5<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">7<\/td>\n<td width=\"184\">Wall Switch Base<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">8<\/td>\n<td width=\"184\">Sound-Activated Switch<\/td>\n<td width=\"184\">118-B30<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">9<\/td>\n<td width=\"184\">Low-Voltage Circuit Breaker<\/td>\n<td width=\"184\">DZ108-20\/10<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">10<\/td>\n<td width=\"184\">Screw-Type Fuse Box<\/td>\n<td width=\"184\">RL1-15\/3A<\/td>\n<td width=\"184\">3<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">11<\/td>\n<td width=\"184\">In-Line Fuse Box<\/td>\n<td width=\"184\">RT14-20\/2A<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">12<\/td>\n<td width=\"184\">AC Contactor<\/td>\n<td width=\"184\">CJX2-0910<\/td>\n<td width=\"184\">3<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">13<\/td>\n<td width=\"184\">Auxiliary Contact<\/td>\n<td width=\"184\">F4-22<\/td>\n<td width=\"184\">3<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">14<\/td>\n<td width=\"184\">Thermal Relay<\/td>\n<td width=\"184\">R16B-20\/3<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">15<\/td>\n<td width=\"184\">Power-On Delay Time Relay<\/td>\n<td width=\"184\">ST3PA-B\/380V (0-60S)<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">16<\/td>\n<td width=\"184\">Time Relay Base<\/td>\n<td width=\"184\">PF-083A<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">17<\/td>\n<td width=\"184\">3H Iron-Cased Button<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">18<\/td>\n<td width=\"184\">Travel Switch<\/td>\n<td width=\"184\">LX9-222<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">19<\/td>\n<td width=\"184\">Travel Switch<\/td>\n<td width=\"184\">LX9-001<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">20<\/td>\n<td width=\"184\">Forward-Reverse Switch<\/td>\n<td width=\"184\">K03-15<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">21<\/td>\n<td width=\"184\">Fluorescent Tube<\/td>\n<td width=\"184\">Y210RR25\/10W<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">22<\/td>\n<td width=\"184\">Ballast<\/td>\n<td width=\"184\">13W<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">23<\/td>\n<td width=\"184\">Fluorescent Lamp Base<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">24<\/td>\n<td width=\"184\">High-Power Resistor<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">3<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">25<\/td>\n<td width=\"184\">Diode<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">26<\/td>\n<td width=\"184\">Terminal Block<\/td>\n<td width=\"184\">JF5-2.5\/5<\/td>\n<td width=\"184\">5<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">27<\/td>\n<td width=\"184\">G-Type Guide Rail<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">28<\/td>\n<td width=\"184\">Wire Duct<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">2 meters<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">29<\/td>\n<td width=\"184\">Screw<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">90<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">30<\/td>\n<td width=\"184\">Screwdriver<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">31<\/td>\n<td width=\"184\">Long-Nose Pliers<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">32<\/td>\n<td width=\"184\">Wire Stripper<\/td>\n<td width=\"184\">&#8211;<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"184\">33<\/td>\n<td width=\"184\">Three-Phase Squirrel-Cage Asynchronous Motor<\/td>\n<td width=\"184\">380V\/Y\/\u25b3 180W<\/td>\n<td width=\"184\">1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Mesh Plate Electrician Training Equipment<\/p>","protected":false},"featured_media":969,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[194],"product_cat":[182],"product_tag":[259],"class_list":{"0":"post-966","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-bhenlab","7":"product_cat-electrician","8":"product_tag-electricianmaintenance-electrician","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/product\/966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/comments?post=966"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/media\/969"}],"wp:attachment":[{"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/media?parent=966"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/product_brand?post=966"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/product_cat?post=966"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bhenlab.com\/es\/wp-json\/wp\/v2\/product_tag?post=966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}